Autodesk Inventor Translation Report
Source File: L:\PfiD\Inventor Files\Vitodens 222 B2TB\Vitodens 222 B2TB-19\Vitodens 222 B2TB-19_With Installation Fittings Horizontal Right.iam
Wednesday, 12/17/2014 (3:17:42 PM)
Published File: L:\PfiD\Inventor Files\Vitodens 222 B2TB\Vitodens 222 B2TB-19\Vitodens 222 B2TB-19_With Installation Fittings Horizontal Right.adsk
Component Type: 23.75.10.11.14.14 Condensing Boilers
Workflow Type: BIM building components Number Of Connections: 8 succeed, 0 fail
Translation Time: 0:00:21.107 Number Of Faces: 170
Sending System: Autodesk Inventor Professional 2012 Complexity Rating: Low
Units: millimeter Bounding Box Size: 703.650 mm x 1662.809 mm x 596.000 mm
Contents
The following table lists the file contents
Generated Contents Status
3D model Successful
2D front view Successful
2D back view Successful
2D left view Successful
2D right view Successful
2D top view Successful
2D bottom view Successful
Properties
Properties included on publish
Identity Data
Description Floor Standing Condensing Boiler with Integrated DHW
Manufacturer Viessmann
Model Vitodens 222 B2TB-19/35
URL www.viessmann.com
Model Properties
Area 3.124908e+007 millimeter^2
Center of Gravity X: 260.502 mm Y: 647.953 mm Z: 275.730 mm
Density 2.215447e-006 lbmass/millimeter^3
Mass 1.910200e+002 lbmass
Requested Accuracy Low
Volume 8.622186e+007 millimeter^3
Cost
Date Created 2014-07-10
Date Checked
Design Status 1
Designer PfiD
Date Eng Approved
Date Mfg Approved
Part Number Vitodens 222-F B2TB-19_With Installation Fittings Horizontal Right
Author PfiD
Connectors
Connector properties included on publish
Electrical Connector Connector:1
System Type Power - Balanced
Description Boiler Control Power Supply
Voltage 120.000 V
Number of Poles 1
Apparent Load 12.000 V A
Load Classification
Motor True
Power Factor
Power Factor State Lagging
Duct Connector Connector:2
System Type Exhaust
Loss Method None
Loss Coefficient
Pressure Drop
Connection Type Undefined
Flow Configuration Preset
Flow
Flow Factor
Flow Direction Bidirectional
Shape Round
Height 0.000 mm
Width 0.000 mm
Radius 1.188 mm
Description Exhaust Vent Pipe
Pipe Connector Connector:3
System Type Hydronic Supply
Allow Slope Adjustment True
Loss Method None
K Coefficient
Pressure Drop
Flow Configuration Preset
Flow Factor
Flow
Flow Direction Out
Connection Type Threaded
Shape Round
Radius 9.525 mm
Description Boiler Supply Pipe
Pipe Connector Connector:4
System Type Domestic Hot Water
Allow Slope Adjustment True
Loss Method None
K Coefficient
Pressure Drop
Flow Configuration Preset
Fixture Units
Flow Factor
Flow
Flow Direction Out
Connection Type Threaded
Shape Round
Radius 9.525 mm
Description Domestic Hot Water Pipe
Pipe Connector Connector:5
System Type Hydronic Return
Allow Slope Adjustment True
Loss Method None
K Coefficient
Pressure Drop
Flow Configuration Preset
Flow Factor
Flow
Flow Direction In
Connection Type Threaded
Shape Round
Radius 9.525 mm
Description Boiler Return Pipe
Pipe Connector Connector:6
System Type Domestic Cold Water
Allow Slope Adjustment True
Loss Method None
K Coefficient
Pressure Drop
Flow Configuration Preset
Fixture Units
Flow Factor
Flow
Flow Direction In
Connection Type Threaded
Shape Round
Radius 9.525 mm
Description Domestic Cold Water Connection
Duct Connector Connector:15
System Type Supply
Loss Method None
Loss Coefficient
Pressure Drop
Connection Type Banded
Flow Configuration Preset
Flow
Flow Factor
Flow Direction In
Shape Round
Height 0.000 mm
Width 0.000 mm
Radius 30.163 mm
Description Combustion Air Intake
Duct Connector Connector:16
System Type Supply
Loss Method None
Loss Coefficient
Pressure Drop
Connection Type Banded
Flow Configuration Preset
Flow
Flow Factor
Flow Direction In
Shape Round
Height 0.000 mm
Width 0.000 mm
Radius 30.163 mm
Description Combustion Air Intake