Autodesk Inventor Translation Report
|
|
Workflow Type: |
BIM building components |
Number Of Connections: |
5 succeed, 0 fail |
Translation Time: |
0:00:42.199 |
Number Of Faces: |
113 |
Sending System: |
Inventor 2018.2 |
Complexity Rating: |
Low |
Units: |
millimeter |
Bounding Box Size: |
666.800 mm x 1733.246 mm x 735.659 mm |
|
Contents
|
The following table lists the file contents |
|
Generated Contents |
Status |
|
3D model |
Successful |
 |
2D front view |
Successful |
|
2D back view |
Successful |
|
2D left view |
Successful |
|
2D right view |
Successful |
|
2D top view |
Successful |
|
2D bottom view |
Successful |
|
|
Properties
|
Properties included on publish |
|
Identity Data |
|
Description |
Indirect-fired Doomestic Hot Water Storage Tank |
Manufacturer |
Viessmann |
Model |
Vitocell 300-V EVIA-300 |
URL |
www.viessmann.com |
|
Connectors
|
Connector properties included on publish |
|
Pipe Connector |
Connector:1 |
System Type |
Domestic Hot Water |
Allow Slope Adjustment |
False |
Loss Method |
None |
K Coefficient |
|
Pressure Drop |
|
Flow Configuration |
Preset |
Fixture Units |
|
Flow Factor |
|
Flow |
|
Flow Direction |
Out |
Connection Type |
Threaded |
Shape |
Round |
Radius |
12.700 mm |
Description |
Domestic Hot Water |
|
Pipe Connector |
Connector:2 |
System Type |
Domestic Hot Water |
Allow Slope Adjustment |
False |
Loss Method |
None |
K Coefficient |
|
Pressure Drop |
|
Flow Configuration |
Preset |
Fixture Units |
|
Flow Factor |
|
Flow |
|
Flow Direction |
In |
Connection Type |
Threaded |
Shape |
Round |
Radius |
12.700 mm |
Description |
Domestic Cold Water |
|
Pipe Connector |
Connector:3 |
System Type |
Domestic Hot Water |
Allow Slope Adjustment |
False |
Loss Method |
None |
K Coefficient |
|
Pressure Drop |
|
Flow Configuration |
Preset |
Fixture Units |
|
Flow Factor |
|
Flow |
|
Flow Direction |
In |
Connection Type |
Threaded |
Shape |
Round |
Radius |
12.700 mm |
Description |
Domestic Hot Water Recirculation |
|
Pipe Connector |
Connector:4 |
System Type |
Hydronic Supply |
Allow Slope Adjustment |
False |
Loss Method |
None |
K Coefficient |
|
Pressure Drop |
|
Flow Configuration |
Preset |
Flow Factor |
|
Flow |
|
Flow Direction |
In |
Connection Type |
Threaded |
Shape |
Round |
Radius |
12.700 mm |
Description |
Boiler Supply |
|
Pipe Connector |
Connector:5 |
System Type |
Hydronic Return |
Allow Slope Adjustment |
False |
Loss Method |
None |
K Coefficient |
|
Pressure Drop |
|
Flow Configuration |
Preset |
Flow Factor |
|
Flow |
|
Flow Direction |
Out |
Connection Type |
Threaded |
Shape |
Round |
Radius |
12.700 mm |
Description |
Boiler Return |
|