Autodesk Inventor Translation Report
Source File: L:\PfiD\Inventor Files\Vitocell\Vitocell 300 EVIA\119 USG 450 L\Vitocell 300-V EVIA-450 - With Jacketing.iam
Friday, 11/10/2017 (4:35:00 PM)
Published File: L:\PfiD\Inventor Files\Vitocell\Vitocell 300 EVIA\119 USG 450 L\Vitocell 300-V EVIA-450.adsk
Component Type: 23.65.35.11.11 Storage Water Heaters
Workflow Type: BIM building components Number Of Connections: 5 succeed, 0 fail
Translation Time: 0:00:17.597 Number Of Faces: 58
Sending System: Autodesk Inventor Professional 2016 Complexity Rating: Low
Units: millimeter Bounding Box Size: 925.000 mm x 1732.000 mm x 982.962 mm
Contents
The following table lists the file contents
Generated Contents Status
3D model Successful
2D front view Successful
2D back view Successful
2D left view Successful
2D right view Successful
2D top view Successful
2D bottom view Successful
Properties
Properties included on publish
Identity Data
Description Indirect Domestic Hot Water Storage Tank
Manufacturer Viessmann
Model Vitocell 300-V EVIA-450
URL www.viessmann.com
Connectors
Connector properties included on publish
Pipe Connector Connector:1
System Type Hydronic Supply
Allow Slope Adjustment True
Loss Method None
K Coefficient
Pressure Drop
Flow Configuration Preset
Flow Factor
Flow
Flow Direction In
Connection Type Threaded
Shape Round
Radius 15.875 mm
Description Boiler Supply
Pipe Connector Connector:2
System Type Hydronic Return
Allow Slope Adjustment True
Loss Method None
K Coefficient
Pressure Drop
Flow Configuration Preset
Flow Factor
Flow
Flow Direction Out
Connection Type Threaded
Shape Round
Radius 15.875 mm
Description Boiler Return
Pipe Connector Connector:3
System Type Domestic Hot Water
Allow Slope Adjustment True
Loss Method None
K Coefficient
Pressure Drop
Flow Configuration Preset
Fixture Units
Flow Factor
Flow
Flow Direction Out
Connection Type Threaded
Shape Round
Radius 15.875 mm
Description Domestic Hot Water
Pipe Connector Connector:4
System Type Domestic Hot Water
Allow Slope Adjustment True
Loss Method None
K Coefficient
Pressure Drop
Flow Configuration Preset
Fixture Units
Flow Factor
Flow
Flow Direction In
Connection Type Threaded
Shape Round
Radius 15.875 mm
Description Domestic Hot Water Recirculation
Pipe Connector Connector:5
System Type Domestic Cold Water
Allow Slope Adjustment True
Loss Method None
K Coefficient
Pressure Drop
Flow Configuration Preset
Fixture Units
Flow Factor
Flow
Flow Direction In
Connection Type Threaded
Shape Round
Radius 15.875 mm
Description Domestic Cold Water