Autodesk Inventor Translation Report
Source File: L:\PfiD\Inventor Files\Low Loss Distribution Manifolds - 2013\Manifold Insulation\4 X B2HB-45 with 200-120 LLH_B2B_With Insulation.iam
Tuesday, 3/19/2019 (2:01:26 PM)
Published File: L:\PfiD\Inventor Files\Low Loss Distribution Manifolds - 2013\Manifold Insulation\4 X B2HB-45 with 200-120 LLH_B2B_With Insulation.adsk
Component Type: 23.75.10.11.14.14 Condensing Boilers
Workflow Type: BIM building components Number Of Connections: 10 succeed, 0 fail
Translation Time: 0:00:40.716 Number Of Faces: 1212
Sending System: Inventor 2019.3 Complexity Rating: Medium
Units: millimeter Bounding Box Size: 2940.356 mm x 1861.026 mm x 2010.000 mm
Contents
The following table lists the file contents
Generated Contents Status
3D model Successful
2D front view Successful
2D back view Successful
2D left view Successful
2D right view Successful
2D top view Successful
2D bottom view Successful
Properties
Properties included on publish
Identity Data
Description 4 Distribution Manifold Back to Back with Insulation
Manufacturer Viessmann
Model 4 X Vitodens 200 B2HB-45
URL www.viessmann.com
Connectors
Connector properties included on publish
Duct Connector Connector:1
System Type Exhaust
Loss Method None
Loss Coefficient
Pressure Drop
Connection Type Undefined
Flow Configuration Preset
Flow
Flow Factor
Flow Direction Bidirectional
Shape Round
Height 0.000 mm
Width 0.000 mm
Radius 63.500 mm
Description Exhaust Vent Pipe
Duct Connector Connector:2
System Type Exhaust
Loss Method None
Loss Coefficient
Pressure Drop
Connection Type Undefined
Flow Configuration Preset
Flow
Flow Factor
Flow Direction Bidirectional
Shape Round
Height 0.000 mm
Width 0.000 mm
Radius 63.500 mm
Description Exhaust Vent Pipe
Pipe Connector Connector:5
System Type Hydronic Supply
Allow Slope Adjustment False
Loss Method None
K Coefficient
Pressure Drop
Flow Configuration Preset
Flow Factor
Flow
Flow Direction Out
Connection Type Flange
Shape Round
Radius 38.100 mm
Description Boiler Supply to System
Pipe Connector Connector:6
System Type Hydronic Return
Allow Slope Adjustment False
Loss Method None
K Coefficient
Pressure Drop
Flow Configuration Preset
Flow Factor
Flow
Flow Direction In
Connection Type Flange
Shape Round
Radius 38.100 mm
Description Return to Boiler
Electrical Connector Connector:7
System Type Power - Balanced
Description Boiler Control Power Supply
Voltage 120.000 V
Number of Poles 1
Apparent Load 12.000 V A
Load Classification
Motor False
Power Factor
Power Factor State Lagging
Electrical Connector Connector:8
System Type Power - Balanced
Description Boiler Control Power Supply
Voltage 120.000 V
Number of Poles 1
Apparent Load 12.000 V A
Load Classification
Motor False
Power Factor
Power Factor State Lagging
Duct Connector Connector:3
System Type Exhaust
Loss Method None
Loss Coefficient
Pressure Drop
Connection Type Undefined
Flow Configuration Preset
Flow
Flow Factor
Flow Direction Bidirectional
Shape Round
Height 0.000 mm
Width 0.000 mm
Radius 63.500 mm
Description Exhaust Vent Pipe
Duct Connector Connector:4
System Type Exhaust
Loss Method None
Loss Coefficient
Pressure Drop
Connection Type Undefined
Flow Configuration Preset
Flow
Flow Factor
Flow Direction Bidirectional
Shape Round
Height 0.000 mm
Width 0.000 mm
Radius 63.500 mm
Description Exhaust Vent Pipe
Electrical Connector Connector:9
System Type Power - Balanced
Description Boiler Control Power Supply
Voltage 120.000 V
Number of Poles 1
Apparent Load 12.000 V A
Load Classification
Motor False
Power Factor
Power Factor State Lagging
Electrical Connector Connector:10
System Type Power - Balanced
Description Boiler Control Power Supply
Voltage 120.000 V
Number of Poles 1
Apparent Load 12.000 V A
Load Classification
Motor False
Power Factor
Power Factor State Lagging