Autodesk Inventor Translation Report
Source File: L:\PfiD\Inventor Files\Vitodens 200 B2HA\Vitodens 200 B2HA 80-100\Vitodens 200 B2HA 80-100 for REVIT.iam
Wednesday, 1/6/2016 (11:57:16 AM)
Published File: C:\Users\pfid\Desktop\Vitodens 200-W B2HA 80-100.adsk
Component Type: 23.75.10.11.14.14 Condensing Boilers
Workflow Type: BIM building components Number Of Connections: 5 succeed, 0 fail
Translation Time: 0:00:32.573 Number Of Faces: 315
Sending System: Autodesk Inventor Professional 2012 Complexity Rating: Low
Units: millimeter Bounding Box Size: 480.000 mm x 1145.944 mm x 533.378 mm
Contents
The following table lists the file contents
Generated Contents Status
3D model Successful
2D front view Successful
2D back view Successful
2D left view Successful
2D right view Successful
2D top view Successful
2D bottom view Successful
Properties
Properties included on publish
Identity Data
Description Vitodens 200 B2HA
Manufacturer Viessmann
Model Vitodens 200 B2HA-80-100
URL www.viessmann.com
Model Properties
Area 2.431666e+007 millimeter^2
Center of Gravity X: -6.442 mm Y: 401.683 mm Z: 290.745 mm
Density 2.376202e-006 lbmass/millimeter^3
Mass 6.420041e+001 lbmass
Requested Accuracy Low
Volume 2.701808e+007 millimeter^3
Cost
Date Created 2013-03-27
Date Checked
Design Status 1
Designer PfiD
Date Eng Approved
Date Mfg Approved
Part Number Vitodens 200 B2HA 80-100 for REVIT
Author PfiD
Connectors
Connector properties included on publish
Pipe Connector Connector:1
System Type Hydronic Supply
Allow Slope Adjustment True
Loss Method None
K Coefficient
Pressure Drop
Flow Configuration Preset
Flow Factor
Flow
Flow Direction Out
Connection Type Threaded
Shape Round
Radius 19.050 mm
Description Boiler Supply
Pipe Connector Connector:2
System Type Hydronic Return
Allow Slope Adjustment True
Loss Method None
K Coefficient
Pressure Drop
Flow Configuration Preset
Flow Factor
Flow
Flow Direction Bidirectional
Connection Type Threaded
Shape Round
Radius 19.050 mm
Description Boiler Return
Pipe Connector Connector:3
System Type Other
Allow Slope Adjustment True
Loss Method None
K Coefficient
Pressure Drop
Flow Configuration Preset
Flow Factor
Flow
Flow Direction In
Connection Type Threaded
Shape Round
Radius 12.700 mm
Description Gas Supply Connection
Electrical Connector Connector:4
System Type Power - Balanced
Description Boiler Power Supply
Voltage 120.000 V
Number of Poles 1
Apparent Load 12.000 V A
Load Classification
Motor True
Power Factor
Power Factor State Lagging
Duct Connector Connector:5
System Type Other
Loss Method None
Loss Coefficient
Pressure Drop
Connection Type Overcollar
Flow Configuration Preset
Flow
Flow Factor
Flow Direction Bidirectional
Shape Round
Height 0.000 mm
Width 0.000 mm
Radius 76.200 mm
Description Boiler Intake/Exhaust