Autodesk Inventor Translation Report
|
|
Workflow Type: |
BIM building components |
Number Of Connections: |
5 succeed, 0 fail |
Translation Time: |
0:00:32.573 |
Number Of Faces: |
315 |
Sending System: |
Autodesk Inventor Professional 2012 |
Complexity Rating: |
Low |
Units: |
millimeter |
Bounding Box Size: |
480.000 mm x 1145.944 mm x 533.378 mm |
|
Contents
|
The following table lists the file contents |
|
Generated Contents |
Status |
|
3D model |
Successful |
 |
2D front view |
Successful |
|
2D back view |
Successful |
|
2D left view |
Successful |
|
2D right view |
Successful |
|
2D top view |
Successful |
|
2D bottom view |
Successful |
|
|
Properties
|
Properties included on publish |
|
Identity Data |
|
Description |
Vitodens 200 B2HA |
Manufacturer |
Viessmann |
Model |
Vitodens 200 B2HA-80-100 |
URL |
www.viessmann.com |
|
Model Properties |
|
Area |
2.431666e+007 millimeter^2 |
Center of Gravity |
X: -6.442 mm Y: 401.683 mm Z: 290.745 mm |
Density |
2.376202e-006 lbmass/millimeter^3 |
Mass |
6.420041e+001 lbmass |
Requested Accuracy |
Low |
Volume |
2.701808e+007 millimeter^3 |
Cost |
|
Date Created |
2013-03-27 |
Date Checked |
|
Design Status |
1 |
Designer |
PfiD |
Date Eng Approved |
|
Date Mfg Approved |
|
Part Number |
Vitodens 200 B2HA 80-100 for REVIT |
Author |
PfiD |
|
Connectors
|
Connector properties included on publish |
|
Pipe Connector |
Connector:1 |
System Type |
Hydronic Supply |
Allow Slope Adjustment |
True |
Loss Method |
None |
K Coefficient |
|
Pressure Drop |
|
Flow Configuration |
Preset |
Flow Factor |
|
Flow |
|
Flow Direction |
Out |
Connection Type |
Threaded |
Shape |
Round |
Radius |
19.050 mm |
Description |
Boiler Supply |
|
Pipe Connector |
Connector:2 |
System Type |
Hydronic Return |
Allow Slope Adjustment |
True |
Loss Method |
None |
K Coefficient |
|
Pressure Drop |
|
Flow Configuration |
Preset |
Flow Factor |
|
Flow |
|
Flow Direction |
Bidirectional |
Connection Type |
Threaded |
Shape |
Round |
Radius |
19.050 mm |
Description |
Boiler Return |
|
Pipe Connector |
Connector:3 |
System Type |
Other |
Allow Slope Adjustment |
True |
Loss Method |
None |
K Coefficient |
|
Pressure Drop |
|
Flow Configuration |
Preset |
Flow Factor |
|
Flow |
|
Flow Direction |
In |
Connection Type |
Threaded |
Shape |
Round |
Radius |
12.700 mm |
Description |
Gas Supply Connection |
|
Electrical Connector |
Connector:4 |
System Type |
Power - Balanced |
Description |
Boiler Power Supply |
Voltage |
120.000 V |
Number of Poles |
1 |
Apparent Load |
12.000 V A |
Load Classification |
|
Motor |
True |
Power Factor |
|
Power Factor State |
Lagging |
|
Duct Connector |
Connector:5 |
System Type |
Other |
Loss Method |
None |
Loss Coefficient |
|
Pressure Drop |
|
Connection Type |
Overcollar |
Flow Configuration |
Preset |
Flow |
|
Flow Factor |
|
Flow Direction |
Bidirectional |
Shape |
Round |
Height |
0.000 mm |
Width |
0.000 mm |
Radius |
76.200 mm |
Description |
Boiler Intake/Exhaust |
|