Autodesk Inventor Translation Report
|
|
Workflow Type: |
BIM building components |
Number Of Connections: |
7 succeed, 0 fail |
Translation Time: |
0:00:32.152 |
Number Of Faces: |
350 |
Sending System: |
Autodesk Inventor Professional 2012 |
Complexity Rating: |
Low |
Units: |
millimeter |
Bounding Box Size: |
581.026 mm x 1084.271 mm x 400.010 mm |
|
Contents
|
The following table lists the file contents |
|
Generated Contents |
Status |
|
3D model |
Successful |
 |
2D front view |
Successful |
|
2D back view |
Successful |
|
2D left view |
Successful |
|
2D right view |
Successful |
|
2D top view |
Successful |
|
2D bottom view |
Successful |
|
|
Properties
|
Properties included on publish |
|
Identity Data |
|
Description |
Wall Mounted Condensing Boiler |
Manufacturer |
Viessmann |
Model |
Vitodens 200-W B2HB-19/26/35 |
URL |
www.viessmann.com |
|
Model Properties |
|
Area |
1.603890e+007 millimeter^2 |
Center of Gravity |
X: 11.326 mm Y: 358.463 mm Z: 208.963 mm |
Density |
1.092408e-006 kilogram/millimeter^3 |
Mass |
1.518105e+001 kilogram |
Requested Accuracy |
Low |
Volume |
1.389687e+007 millimeter^3 |
Cost |
|
Date Created |
2014-09-16 |
Date Checked |
|
Design Status |
1 |
Designer |
pfid |
Date Eng Approved |
|
Date Mfg Approved |
|
Part Number |
Vitodens 200-W B2HB-26-35 with Installation Fittings |
Author |
pfid |
|
Connectors
|
Connector properties included on publish |
|
Electrical Connector |
Connector:1 |
System Type |
Power - Balanced |
Description |
Boiler Power Supply |
Voltage |
120.000 V |
Number of Poles |
1 |
Apparent Load |
12.000 V A |
Load Classification |
|
Motor |
True |
Power Factor |
|
Power Factor State |
Lagging |
|
Pipe Connector |
Connector:2 |
System Type |
Hydronic Return |
Allow Slope Adjustment |
True |
Loss Method |
None |
K Coefficient |
|
Pressure Drop |
|
Flow Configuration |
Preset |
Flow Factor |
|
Flow |
|
Flow Direction |
In |
Connection Type |
Threaded |
Shape |
Round |
Radius |
9.525 mm |
Description |
Boiler Return |
|
Pipe Connector |
Connector:3 |
System Type |
Hydronic Supply |
Allow Slope Adjustment |
True |
Loss Method |
None |
K Coefficient |
|
Pressure Drop |
|
Flow Configuration |
Preset |
Flow Factor |
|
Flow |
|
Flow Direction |
Out |
Connection Type |
Threaded |
Shape |
Round |
Radius |
9.525 mm |
Description |
Boiler Supply |
|
Pipe Connector |
Connector:4 |
System Type |
Other |
Allow Slope Adjustment |
True |
Loss Method |
None |
K Coefficient |
|
Pressure Drop |
|
Flow Configuration |
Preset |
Flow Factor |
|
Flow |
|
Flow Direction |
In |
Connection Type |
Threaded |
Shape |
Round |
Radius |
9.525 mm |
Description |
Gas Connection |
|
Duct Connector |
Connector:5 |
System Type |
Exhaust |
Loss Method |
None |
Loss Coefficient |
|
Pressure Drop |
|
Connection Type |
Undefined |
Flow Configuration |
Preset |
Flow |
|
Flow Factor |
|
Flow Direction |
Out |
Shape |
Round |
Height |
0.000 mm |
Width |
0.000 mm |
Radius |
30.163 mm |
Description |
Boiler Flue Connection |
|
Duct Connector |
Connector:6 |
System Type |
Supply |
Loss Method |
None |
Loss Coefficient |
|
Pressure Drop |
|
Connection Type |
Banded |
Flow Configuration |
Preset |
Flow |
|
Flow Factor |
|
Flow Direction |
In |
Shape |
Round |
Height |
0.000 mm |
Width |
0.000 mm |
Radius |
30.163 mm |
Description |
Combustion Air Intake |
|
Duct Connector |
Connector:7 |
System Type |
Supply |
Loss Method |
None |
Loss Coefficient |
|
Pressure Drop |
|
Connection Type |
Banded |
Flow Configuration |
Preset |
Flow |
|
Flow Factor |
|
Flow Direction |
In |
Shape |
Round |
Height |
0.000 mm |
Width |
0.000 mm |
Radius |
30.163 mm |
Description |
Combustion Air Intake |
|