Autodesk Inventor Translation Report
|
|
Workflow Type: |
BIM building components |
Number Of Connections: |
7 succeed, 0 fail |
Translation Time: |
0:00:15.569 |
Number Of Faces: |
258 |
Sending System: |
Autodesk Inventor Professional 2016 |
Complexity Rating: |
Low |
Units: |
millimeter |
Bounding Box Size: |
1466.795 mm x 2131.153 mm x 2573.000 mm |
|
Contents
|
The following table lists the file contents |
|
Generated Contents |
Status |
|
3D model |
Successful |
 |
2D front view |
Successful |
|
2D back view |
Successful |
|
2D left view |
Successful |
|
2D right view |
Successful |
|
2D top view |
Successful |
|
2D bottom view |
Successful |
|
|
Properties
|
Properties included on publish |
|
Identity Data |
|
Description |
Dual Fuel Commercial Condensing Boiler |
Manufacturer |
Viessmann |
Model |
Vitocrossal 300 Dual Fuel CA3 - 2.5 |
URL |
www.Viessmann.com |
|
Connectors
|
Connector properties included on publish |
|
Pipe Connector |
Connector:1 |
System Type |
Hydronic Supply |
Allow Slope Adjustment |
True |
Loss Method |
None |
K Coefficient |
|
Pressure Drop |
|
Flow Configuration |
Preset |
Flow Factor |
|
Flow |
|
Flow Direction |
Out |
Connection Type |
Flange |
Shape |
Round |
Radius |
50.800 mm |
Description |
Boiler Supply Connection |
|
Pipe Connector |
Connector:2 |
System Type |
Other |
Allow Slope Adjustment |
True |
Loss Method |
None |
K Coefficient |
|
Pressure Drop |
|
Flow Configuration |
Preset |
Flow Factor |
|
Flow |
|
Flow Direction |
In |
Connection Type |
Threaded |
Shape |
Round |
Radius |
19.050 mm |
Description |
Liquid Propane Gas Connection |
|
Pipe Connector |
Connector:3 |
System Type |
Other |
Allow Slope Adjustment |
True |
Loss Method |
None |
K Coefficient |
|
Pressure Drop |
|
Flow Configuration |
Preset |
Flow Factor |
|
Flow |
|
Flow Direction |
In |
Connection Type |
Threaded |
Shape |
Round |
Radius |
31.750 mm |
Description |
Natural Gas Connection |
|
Pipe Connector |
Connector:4 |
System Type |
Hydronic Return |
Allow Slope Adjustment |
True |
Loss Method |
None |
K Coefficient |
|
Pressure Drop |
|
Flow Configuration |
Preset |
Flow Factor |
|
Flow |
|
Flow Direction |
In |
Connection Type |
Flange |
Shape |
Round |
Radius |
50.800 mm |
Description |
Boiler Return Connection |
|
Electrical Connector |
Connector:5 |
System Type |
Power - Balanced |
Description |
Boiler Power Supply Connection |
Voltage |
120.000 V |
Number of Poles |
1 |
Apparent Load |
21.000 V A |
Load Classification |
|
Motor |
True |
Power Factor |
|
Power Factor State |
Lagging |
|
Duct Connector |
Connector:6 |
System Type |
Exhaust |
Loss Method |
None |
Loss Coefficient |
|
Pressure Drop |
|
Connection Type |
Banded |
Flow Configuration |
Preset |
Flow |
|
Flow Factor |
|
Flow Direction |
Out |
Shape |
Round |
Height |
0.000 mm |
Width |
0.000 mm |
Radius |
152.400 mm |
Description |
Boiler Flue Connection |
|
Duct Connector |
Connector:7 |
System Type |
Supply |
Loss Method |
None |
Loss Coefficient |
|
Pressure Drop |
|
Connection Type |
Banded |
Flow Configuration |
Preset |
Flow |
|
Flow Factor |
|
Flow Direction |
In |
Shape |
Round |
Height |
0.000 mm |
Width |
0.000 mm |
Radius |
152.400 mm |
Description |
Boiler Combustion Air Intake Connection |
|