Autodesk Inventor Translation Report
Source File: L:\PfiD\Inventor Files\Vitocrossal 300 CU3A\Vitocrossal 300 CU3A-45\Vitocrossal 300 CU3A-45.iam
Thursday, 4/2/2015 (11:10:51 AM)
Published File: L:\PfiD\Inventor Files\Vitocrossal 300 CU3A\Vitocrossal 300 CU3A-45\Vitocrossal 300 CU3A-45.adsk
Component Type: No classification
Workflow Type: BIM building components Number Of Connections: 6 succeed, 0 fail
Translation Time: 0:00:20.935 Number Of Faces: 120
Sending System: Autodesk Inventor Professional 2012 Complexity Rating: Low
Units: millimeter Bounding Box Size: 660.000 mm x 1559.575 mm x 794.633 mm
Contents
The following table lists the file contents
Generated Contents Status
3D model Successful
2D front view Successful
2D back view Successful
2D left view Successful
2D right view Successful
2D top view Successful
2D bottom view Successful
Properties
Properties included on publish
Identity Data
Description Residential Floor Mounted Condensing Boiler
Manufacturer Viessmann
Model Vitocrossal 300 CU3A-45
URL www.veissmann.com
Model Properties
Area 4.435413e+007 millimeter^2
Center of Gravity X: -0.619 mm Y: -145.596 mm Z: -232.052 mm
Density 2.204622e-006 lbmass/millimeter^3
Mass 3.933157e+002 lbmass
Requested Accuracy Low
Volume 1.784050e+008 millimeter^3
Cost
Date Created 2015-02-03
Date Checked
Design Status 1
Designer pfid
Date Eng Approved
Date Mfg Approved
Part Number Vitocrossal 300 CU3A-45
Author pfid
Connectors
Connector properties included on publish
Electrical Connector Connector:1
System Type Power - Balanced
Description Boiler Power Supply
Voltage 120.000 V
Number of Poles 1
Apparent Load 15.000 V A
Load Classification
Motor True
Power Factor
Power Factor State Lagging
Duct Connector Connector:2
System Type Exhaust
Loss Method None
Loss Coefficient
Pressure Drop
Connection Type Slip Joint
Flow Configuration Preset
Flow
Flow Factor
Flow Direction Out
Shape Round
Height 0.000 mm
Width 0.000 mm
Radius 50.800 mm
Description Boiler Flue Connection
Duct Connector Connector:3
System Type Supply
Loss Method None
Loss Coefficient
Pressure Drop
Connection Type Slip Joint
Flow Configuration Preset
Flow
Flow Factor
Flow Direction In
Shape Round
Height 0.000 mm
Width 0.000 mm
Radius 38.100 mm
Description Boiler Combustion Air Connection
Pipe Connector Connector:4
System Type Hydronic Return
Allow Slope Adjustment True
Loss Method None
K Coefficient
Pressure Drop
Flow Configuration Preset
Flow Factor
Flow
Flow Direction In
Connection Type Threaded
Shape Round
Radius 15.875 mm
Description Boiler Return Connection
Pipe Connector Connector:5
System Type Hydronic Supply
Allow Slope Adjustment True
Loss Method None
K Coefficient
Pressure Drop
Flow Configuration Preset
Flow Factor
Flow
Flow Direction Out
Connection Type Threaded
Shape Round
Radius 15.875 mm
Description Boiler Supply Connection
Pipe Connector Connector:6
System Type Other
Allow Slope Adjustment True
Loss Method None
K Coefficient
Pressure Drop
Flow Configuration Preset
Flow Factor
Flow
Flow Direction In
Connection Type Threaded
Shape Round
Radius 9.525 mm
Description Boiler Gas Connection