Autodesk Inventor Translation Report
|
|
Workflow Type: |
BIM building components |
Number Of Connections: |
4 succeed, 0 fail |
Translation Time: |
0:00:22.339 |
Number Of Faces: |
408 |
Sending System: |
Autodesk Inventor Professional 2012 |
Complexity Rating: |
Low |
Units: |
millimeter |
Bounding Box Size: |
580.895 mm x 1187.389 mm x 655.271 mm |
|
Contents
|
The following table lists the file contents |
|
Generated Contents |
Status |
|
3D model |
Successful |
 |
2D front view |
Successful |
|
2D back view |
Successful |
|
2D left view |
Successful |
|
2D right view |
Successful |
|
2D top view |
Successful |
|
2D bottom view |
Successful |
|
|
Properties
|
Properties included on publish |
|
Identity Data |
|
Description |
Indirect-fired Domestic Hot Water Storage Tank |
Manufacturer |
Viessmann |
Model |
Vitocell-V 100 CVA-160 |
URL |
www.viessmann.com |
|
Model Properties |
|
Area |
1.554058e+007 millimeter^2 |
Center_of_Gravity |
|
Density |
2.225924e-006 lbmass/millimeter^3 |
Mass |
2.442249e+002 lbmass |
Requested_Accuracy |
|
Volume |
1.097184e+008 millimeter^3 |
Cost |
|
Creation_Time |
|
Date_Checked |
|
Description |
|
Design_Status |
|
Designer |
PfiD |
Engr_Date_Approved |
|
Mfg_Date_Approved |
|
Part_Number |
|
Author |
PfiD |
Title |
|
|
Connectors
|
Connector properties included on publish |
|
Pipe Connector |
Connector:1 |
System Type |
Domestic Hot Water |
Allow Slope Adjustment |
True |
Loss Method |
None |
K Coefficient |
|
Pressure Drop |
|
Flow Configuration |
Preset |
Fixture Units |
|
Flow Factor |
|
Flow |
|
Flow Direction |
Out |
Connection Type |
Threaded |
Shape |
Round |
Radius |
9.525 mm |
Description |
Domestic Hot Water |
|
Pipe Connector |
Connector:2 |
System Type |
Domestic Cold Water |
Allow Slope Adjustment |
True |
Loss Method |
None |
K Coefficient |
|
Pressure Drop |
|
Flow Configuration |
Preset |
Fixture Units |
|
Flow Factor |
|
Flow |
|
Flow Direction |
In |
Connection Type |
Threaded |
Shape |
Round |
Radius |
9.525 mm |
Description |
Domestic Cold Water |
|
Pipe Connector |
Connector:3 |
System Type |
Hydronic Supply |
Allow Slope Adjustment |
True |
Loss Method |
None |
K Coefficient |
|
Pressure Drop |
|
Flow Configuration |
Preset |
Flow Factor |
|
Flow |
|
Flow Direction |
In |
Connection Type |
Threaded |
Shape |
Round |
Radius |
12.700 mm |
Description |
Supply from Boiler |
|
Pipe Connector |
Connector:4 |
System Type |
Hydronic Return |
Allow Slope Adjustment |
True |
Loss Method |
None |
K Coefficient |
|
Pressure Drop |
|
Flow Configuration |
Preset |
Flow Factor |
|
Flow |
|
Flow Direction |
In |
Connection Type |
Threaded |
Shape |
Round |
Radius |
12.700 mm |
Description |