Autodesk Inventor Translation Report
|
|
Workflow Type: |
BIM building components |
Number Of Connections: |
4 succeed, 0 fail |
Translation Time: |
0:00:12.776 |
Number Of Faces: |
69 |
Sending System: |
Autodesk Inventor Professional 2012 |
Complexity Rating: |
Low |
Units: |
millimeter |
Bounding Box Size: |
400.000 mm x 1600.300 mm x 799.400 mm |
|
Contents
|
The following table lists the file contents |
|
Generated Contents |
Status |
|
3D model |
Successful |
 |
2D front view |
Successful |
|
2D back view |
Successful |
|
2D left view |
Successful |
|
2D right view |
Successful |
|
2D top view |
Successful |
|
2D bottom view |
Successful |
|
|
Properties
|
Properties included on publish |
|
Identity Data |
|
Description |
Low Loss Header |
Manufacturer |
Viessmann |
Model |
LLH 400-200 |
URL |
www.viessmann.com |
|
Model Properties |
|
Area |
5.200326e+006 millimeter^2 |
Center_of_Gravity |
|
Density |
3.201019e-006 kilogram/millimeter^3 |
Mass |
7.074691e+001 kilogram |
Requested_Accuracy |
|
Volume |
2.210137e+007 millimeter^3 |
Cost |
|
Creation_Time |
|
Date_Checked |
|
Description |
|
Design_Status |
|
Designer |
smhg |
Engr_Date_Approved |
|
Mfg_Date_Approved |
|
Part_Number |
|
Author |
smhg |
Title |
|
|
Connectors
|
Connector properties included on publish |
|
Pipe Connector |
Connector:9 |
System Type |
Hydronic Supply |
Allow Slope Adjustment |
True |
Loss Method |
None |
K Coefficient |
|
Pressure Drop |
|
Flow Configuration |
Preset |
Flow Factor |
|
Flow |
|
Flow Direction |
In |
Connection Type |
Flange |
Shape |
Round |
Radius |
76.200 mm |
Description |
Boiler Supply Pipe |
|
Pipe Connector |
Connector:10 |
System Type |
Hydronic Supply |
Allow Slope Adjustment |
True |
Loss Method |
None |
K Coefficient |
|
Pressure Drop |
|
Flow Configuration |
Preset |
Flow Factor |
|
Flow |
|
Flow Direction |
Out |
Connection Type |
Flange |
Shape |
Round |
Radius |
76.200 mm |
Description |
System Supply Pipe |
|
Pipe Connector |
Connector:11 |
System Type |
Hydronic Return |
Allow Slope Adjustment |
True |
Loss Method |
None |
K Coefficient |
|
Pressure Drop |
|
Flow Configuration |
Preset |
Flow Factor |
|
Flow |
|
Flow Direction |
Out |
Connection Type |
Flange |
Shape |
Round |
Radius |
76.200 mm |
Description |
Boiler Return Pipe |
|
Pipe Connector |
Connector:12 |
System Type |
Hydronic Return |
Allow Slope Adjustment |
True |
Loss Method |
None |
K Coefficient |
|
Pressure Drop |
|
Flow Configuration |
Preset |
Flow Factor |
|
Flow |
|
Flow Direction |
In |
Connection Type |
Flange |
Shape |
Round |
Radius |
76.200 mm |
Description |
System Return Pipe |
|