Autodesk Inventor Translation Report
Source File: L:\PfiD\Inventor Files\Vitorond 200 VD2A\VD2A-195\Vitorond 200 VD2A-195 With Weishaupt WG30.iam
Wednesday, 12/10/2014 (3:18:03 PM)
Published File: L:\PfiD\Inventor Files\Vitorond 200 VD2A\VD2A-195\Vitorond 200 VD2A-195 With Weishaupt WG30.adsk
Component Type: 23.75.10.11.14.11 Cast-Iron Boilers
Workflow Type: BIM building components Number Of Connections: 4 succeed, 0 fail
Translation Time: 0:00:24.976 Number Of Faces: 248
Sending System: Autodesk Inventor Professional 2012 Complexity Rating: Low
Units: millimeter Bounding Box Size: 1027.429 mm x 1487.300 mm x 1685.401 mm
Contents
The following table lists the file contents
Generated Contents Status
3D model Successful
2D front view Successful
2D back view Successful
2D left view Successful
2D right view Successful
2D top view Successful
2D bottom view Successful
Properties
Properties included on publish
Identity Data
Description Commercial Sectional Cast Iron Boiler
Manufacturer Viessmann
Model Vitorond 200 VD2A-195
URL www.viessmann.com
Model Properties
Area 2.243866e+007 millimeter^2
Center of Gravity X: -10.115 mm Y: 472.912 mm Z: 331.935 mm
Density 1.045613e-006 kilogram/millimeter^3
Mass 1.657171e+002 kilogram
Requested Accuracy Low
Volume 1.584879e+008 millimeter^3
Cost
Date Created 2014-07-07
Date Checked
Design Status 1
Designer smhg
Date Eng Approved
Date Mfg Approved
Part Number Vitorond 200 VD2A-195 With Weishaupt WG30
Author smhg
Connectors
Connector properties included on publish
Duct Connector Connector:5
System Type Exhaust
Loss Method None
Loss Coefficient
Pressure Drop
Connection Type Undefined
Flow Configuration Preset
Flow
Flow Factor
Flow Direction Out
Shape Round
Height 0.000 mm
Width 0.000 mm
Radius 101.600 mm
Description Exhaust Vent Pipe
Electrical Connector Connector:6
System Type Power - Balanced
Description Boiler Control Power Supply
Voltage 120.000 V
Number of Poles 1
Apparent Load 12.000 V A
Load Classification
Motor True
Power Factor
Power Factor State Lagging
Pipe Connector Connector:7
System Type Hydronic Supply
Allow Slope Adjustment True
Loss Method None
K Coefficient
Pressure Drop
Flow Configuration Preset
Flow Factor
Flow
Flow Direction Out
Connection Type Threaded
Shape Round
Radius 31.750 mm
Description Boiler Supply Pipe
Pipe Connector Connector:9
System Type Hydronic Return
Allow Slope Adjustment True
Loss Method None
K Coefficient
Pressure Drop
Flow Configuration Preset
Flow Factor
Flow
Flow Direction In
Connection Type Threaded
Shape Round
Radius 31.750 mm
Description Boiler Return Pipe