Autodesk Inventor Translation Report
Source File: L:\PfiD\Inventor Files\Vitoligno 300-C\Vitoligno 300-C VL3C-32\Vitoligno 300-C VL3C-32 - With Installation Fittings and Shunt System.iam
Wednesday, 5/3/2017 (2:00:58 PM)
Published File: C:\Users\pfid\Desktop\Vitoligno 300-C VL3C-32 - With Installation Fittings and Shunt System.iam (SubstituteLevelofDetail11).adsk
Component Type: 23.75.10.11.14.21 Firebox Heating Boilers
Workflow Type: BIM building components Number Of Connections: 6 succeed, 0 fail
Translation Time: 0:00:39.593 Number Of Faces: 3957
Sending System: Autodesk Inventor Professional 2016 Complexity Rating: High
Units: millimeter Bounding Box Size: 1331.617 mm x 1562.000 mm x 1397.513 mm
Contents
The following table lists the file contents
Generated Contents Status
3D model Successful
2D front view Successful
2D back view Successful
2D left view Successful
2D right view Successful
2D top view Successful
2D bottom view Successful
Properties
Properties included on publish
Identity Data
Description Wood Pellet Fired Residential Boiler
Manufacturer Viessmann
Model Vitoligno 300-C VL3C-32 - With Vacuum System
URL www.viessmann.com
Connectors
Connector properties included on publish
Electrical Connector Connector:1
System Type Power - Balanced
Description Boiler Power Supplu Connection
Voltage 240.000 V
Number of Poles 1
Apparent Load 20.000 V A
Load Classification
Motor True
Power Factor
Power Factor State Lagging
Pipe Connector Connector:2
System Type Hydronic Supply
Allow Slope Adjustment True
Loss Method None
K Coefficient
Pressure Drop
Flow Configuration Preset
Flow Factor
Flow
Flow Direction Out
Connection Type Threaded
Shape Round
Radius 19.050 mm
Description Boiler Supplu Connection
Pipe Connector Connector:3
System Type Hydronic Return
Allow Slope Adjustment True
Loss Method None
K Coefficient
Pressure Drop
Flow Configuration Preset
Flow Factor
Flow
Flow Direction In
Connection Type Threaded
Shape Round
Radius 19.050 mm
Description Boiler Return Connection
Pipe Connector Connector:4
System Type Other
Allow Slope Adjustment True
Loss Method None
K Coefficient
Pressure Drop
Flow Configuration Preset
Flow Factor
Flow
Flow Direction In
Connection Type Slip Joint
Shape Round
Radius 25.400 mm
Description Pellet Vacuum Suction Side
Pipe Connector Connector:5
System Type Other
Allow Slope Adjustment True
Loss Method None
K Coefficient
Pressure Drop
Flow Configuration Preset
Flow Factor
Flow
Flow Direction Out
Connection Type Slip Joint
Shape Round
Radius 25.400 mm
Description Return Air Vacuum System
Duct Connector Connector:6
System Type Exhaust
Loss Method None
Loss Coefficient
Pressure Drop
Connection Type Banded
Flow Configuration Preset
Flow
Flow Factor
Flow Direction Out
Shape Round
Height 0.000 mm
Width 0.000 mm
Radius 76.200 mm
Description Boiler Flue Connection