Autodesk Inventor Translation Report
|
|
Workflow Type: |
BIM building components |
Number Of Connections: |
4 succeed, 0 fail |
Translation Time: |
0:00:28.454 |
Number Of Faces: |
218 |
Sending System: |
Autodesk Inventor Professional 2012 |
Complexity Rating: |
Low |
Units: |
inch |
Bounding Box Size: |
22.216 in x 45.858 in x 33.130 in |
|
Contents
|
The following table lists the file contents |
|
Generated Contents |
Status |
|
3D model |
Successful |
 |
2D front view |
Successful |
|
2D back view |
Successful |
|
2D left view |
Successful |
|
2D right view |
Successful |
|
2D top view |
Successful |
|
2D bottom view |
Successful |
|
|
Properties
|
Properties included on publish |
|
Identity Data |
|
Description |
Sectional Cast Iron Boiler With Vitotronic 100 KW10B and Chimney Vent |
Manufacturer |
Viessmann |
Model |
Vitorond 100 VR1-40 |
URL |
www.viessmann.com |
|
Model Properties |
|
Area |
2.336927e+004 inch^2 |
Center_of_Gravity |
|
Density |
3.612729e-002 lbmass/inch^3 |
Mass |
1.251002e+002 lbmass |
Requested_Accuracy |
|
Volume |
3.462761e+003 inch^3 |
Cost |
|
Creation_Time |
|
Date_Checked |
|
Description |
|
Design_Status |
|
Designer |
smhg |
Engr_Date_Approved |
|
Mfg_Date_Approved |
|
Part_Number |
|
Author |
smhg |
Title |
|
|
Connectors
|
Connector properties included on publish |
|
Duct Connector |
Connector:1 |
System Type |
Exhaust |
Loss Method |
None |
Loss Coefficient |
|
Pressure Drop |
|
Connection Type |
Banded |
Flow Configuration |
Preset |
Flow |
|
Flow Factor |
|
Flow Direction |
Out |
Shape |
Round |
Height |
0.000 in |
Width |
0.000 in |
Radius |
3.000 in |
Description |
Boiler Vent Connection |
|
Pipe Connector |
Connector:2 |
System Type |
Hydronic Supply |
Allow Slope Adjustment |
True |
Loss Method |
None |
K Coefficient |
|
Pressure Drop |
|
Flow Configuration |
Preset |
Flow Factor |
|
Flow |
|
Flow Direction |
Out |
Connection Type |
Threaded |
Shape |
Round |
Radius |
1.000 in |
Description |
Boiler Supply |
|
Pipe Connector |
Connector:3 |
System Type |
Hydronic Return |
Allow Slope Adjustment |
True |
Loss Method |
None |
K Coefficient |
|
Pressure Drop |
|
Flow Configuration |
Preset |
Flow Factor |
|
Flow |
|
Flow Direction |
In |
Connection Type |
Threaded |
Shape |
Round |
Radius |
1.000 in |
Description |
Boiler Return |
|
Electrical Connector |
Connector:4 |
System Type |
Power - Balanced |
Description |
Boiler Control Power Supply |
Voltage |
120.000 V |
Number of Poles |
1 |
Apparent Load |
12.000 V A |
Load Classification |
|
Motor |
True |
Power Factor |
|
Power Factor State |
Lagging |
|